6 Watt Single Series DC/DC Converters
Features
! ! ! ! ! !
Low Profile Copper Case (0.375" High) Six-Sided Shielded Case Low Input/Output Noise Operation 500 VDC Minimum Input to Output Isolation Output Overvoltage Clamp Fixed Frequency Operation Independent of Line and Load Highly Regulated/Low Drift Output Rugged High Speed MOSFET Power Chopper 5 Year Warranty
! ! !
Description
These 6 Watt Single Output DC/DC converters are suitable for telecommunications and industrial control applications that call for direct PCB mounting. The converters in this series are designed with an LC input filter, a MOSFET push-pull power chopper, and an isolation transformer. A linear post regulator provides excellent line and load regulation. Noise is reduced by housing each unit in a six-sided shielded copper case. The CALEX 5 Year Warranty covers all converters in this series.
Model 12S5.1000 12S12.500 12S15.400 24S5.1000 24S12.500 24S15.400 28S5.1000 28S12.500 28S15.400 48S5.1000 48S12.500 48S15.400
Selection Chart
Input Range VDC Min Max 11.16 13.20 11.16 13.20 11.16 13.20 22.32 26.40 22.32 26.40 22.32 26.40 26.04 30.80 26.04 30.80 26.04 30.80 44.64 52.80 44.64 52.80 44.64 52.80 Output VDC 5.0 12.0 15.0 5.0 12.0 15.0 5.0 12.0 15.0 5.0 12.0 15.0 Output mA 1000 500 400 1000 500 400 1000 500 400 1000 500 400
6 Watt Single Output Series Block Diagram
ISOLATION TRANSFORMER
LOW VOLTAGE CURRENT LIMIT
A
3 + OUTPUT
+ INPUT 1 - INPUT 2
LC INPUT FILTER
FIXED FREQUENCY POWER DRIVER LOW TC REFERENCE
C1
D1
5 CMN
Output
C1
D1
5 12 15
47F 22F 22F
6.8V N/A N/A
SIX-SIDED SHIELDED COPPER CASE
2401 Stanwell Drive * Concord, California 94520 * Ph: 925/687-4411 or 800/542-3355 * Fax: 925/687-3333 * www.calex.com * Email: sales@calex.com
1
3/2001
www..com
6 Watt Single Series DC/DC Converters
Input Parameters*
Model Voltage Range (13) Reflected Ripple (2), 0-20MHz bw Input Current Full Load No Load Efficiency Switching Frequency Maximum Input Overvoltage, 100ms No Damage Turn-on Time, 1% Output Error (3) Recommended Fuse Model Voltage Range Reflected Ripple (2), 0-20MHz bw Input Current Full Load No Load Efficiency Switching Frequency Maximum Input Overvoltage, 100ms No Damage Turn-on Time, 1% Output Error (3) Recommended Fuse MIN MAX TYP MAX TYP TYP TYP TYP MAX TYP 35 1 Slow Blow Type (4) 28S5.1000 28S12.500 26.04 30.80 3 10 318 19 67 MIN MAX TYP MAX TYP TYP TYP TYP MAX TYP 28S15.400 15 1 Slow Blow Type (4) 48S5.1000 48S12.500 44.64 52.80 10 20 190 16 66 48S15.400 Units VDC mA P-P 185 17 68 mA % kHz 60 VDC ms 12S5.1000 12S12.500 11.16 13.20 7 15 740 43 68 12S15.400 24S5.1000 24S12.500 22.32 26.40 5 10 370 23 68 24S15.400 Units VDC mA P-P 360 27 69 mA % kHz 30 VDC ms
700 43 60
720 54 69 55
330 20 63
288 19 62
309 21 69 55
170 16 60
Output Parameters*
Model Output Voltage Rated Load (5) Voltage Range 100% Load Load Regulation 0-100% Load Line Regulation Vin = Min-Max VDC Short Term Stability (6) Long Term Stability Transient Response (7) Dynamic Response (8) Input Ripple Rejection (9) Noise, 0-20MHz bw (2) Temperature Coefficient Overvoltage Clamp (10) Short Circuit Protection to Common for all Outputs MIN MAX MIN TYP MAX TYP MAX TYP MAX TYP TYP TYP TYP TYP TYP MAX TYP MAX TYP 120 12S5.1000 28S5.1000 24S5.1000 48S5.1000 12S12.500 28S12.500 24S12.500 48S12.500 12S15.400 28S15.400 24S15.400 48S15.400 Units VDC mA VDC % % %
5 0 1000 4.95 5.00 5.05
12 0 500 11.90 12.00 12.10 0.02 0.15 0.02 0.10 0.02 0.20 20 55 60 10 40 50 200 -
15 0 400 14.90 15.00 15.10
A
50
%/kHrs s mV peak dB mV P-P ppm/C VDC
6.8
Short Term, 1 Minute Maximum (4)
NOTES measured at Tc=25C, * All parameters load unless otherwisenominal input voltage and full rated noted. Refer to the CALEX Application Notes for the definition of terms, measurement circuits and other information. (2) Noise is measured per CALEX Application Notes. (3) Turn-on time is defined as the time from the application of power until the output is within 1% of its final value.
(4)
(5) (6)
For long term short circuit protection of the converters, install a slow blow fuse in the input circuit. Choose a fuse size that is 125% of your applications actual input current and does not exceed 115% of the full load input current. No minimum load required. Short term stability is specified after a 30 minute warm-up at full load, and with constant line, load and ambient conditions.
2401 Stanwell Drive * Concord, California 94520 * Ph: 925/687-4411 or 800/542-3355 * Fax: 925/687-3333 * www.calex.com * Email: sales@calex.com
2
3/2001
6 Watt Single Series DC/DC Converters
General Specifications*
All Models Isolation Isolation Voltage 10A Leakage Input-Output Input to Output Capacitance Environmental Case Operating Range No Derating Units
MIN TYP
700 75 -25 80 -40 85 -55 90 10 1.7 MS6, MS8, MS15
VDC pF
MIN MAX MIN Case Functional Range (11) MAX MIN Storage Range MAX Thermal Impedance (12) TYP General TYP
C C C C/Watt oz BOTTOM VIEW Mechanical tolerances unless otherwise noted: X.XX dimensions: 0.020 inches X.XXX dimensions: 0.005 inches Seal around terminals is not hermetic. Do not immerse units in any liquid. SIDE VIEW
Unit Weight Chassis Mounting Kits
After a 100% step change of the load, the output voltage will be within 1% of the final value within the transient response time. (8) Dynamic response is the peak overshoot voltage during the transient response time defined in note 7 above. (9) The input ripple rejection is specified for DC to 120Hz ripple with a modulation amplitude of 1% Vin. (10) For module protection only, see also Note 4. (11) The functional temperature range is intended to give an additional data point for use in evaluating this power supply. At the low functional temperature the power supply will function with no side effects, however sustained operation at the high functional temperature will reduce expected operational life. The data sheet specifications are not guaranteed over the functional temperature range.
(7)
Pin 1 2 3 5
Function +INPUT -INPUT +OUTPUT CMN
(12) The Case Thermal Impedance is specified as the case temperature rise over ambient per package watt dissipated. (13) Input voltage range is 10.56 - 15.60 VDC when total output power is 3 watts or less. (14) Specifications subject to change without notice.
Typical Performance: (Tc = 25C; Full Rated Load).
12S5.1000 EFFICIENCY Vs. LINE INPUT
70 70
12S15.400 EFFICIENCY Vs. LINE INPUT
0.8
12 VOLT INPUT CURRENT Vs. LINE INPUT VOLTAGE
EFFICIENCY (%)
65
EFFICIENCY (%)
65
INPUT CURRENT (AMPS)
100% FULL LOAD
0.6
100% FULL LOAD 50% FULL LOAD
60
100% FULL LOAD
60
0.4
A
50% FULL LOAD
4 6 8 10 12 14
55
0.2
50% FULL LOAD
55 11.0 11.5 12.0 12.5 13.0 13.5 50 11.0 11.5 12.0 12.5 13.0 13.5 0.0
LINE INPUT (VOLTS)
LINE INPUT (VOLTS)
LINE INPUT (VOLTS)
24S5.1000 EFFICIENCY Vs. LINE INPUT
70 80
24S15.400 EFFICIENCY Vs. LINE INPUT
0.40
24 VOLT INPUT CURRENT Vs. LINE INPUT VOLTAGE
100% FULL LOAD
EFFICIENCY (%)
65
EFFICIENCY (%)
75
INPUT CURRENT (AMPS)
100% FULL LOAD
0.30
100% FULL LOAD
70
0.20
50% FULL LOAD
60
50% FULL LOAD
65
50% FULL LOAD
0.10
55 22 23 24 25 26 27
60 22 23 24 25 26 27
0.00 10 15 20 25 30
LINE INPUT (VOLTS)
LINE INPUT (VOLTS)
OPERATING RANGE LINE INPUT (VOLTS)
2401 Stanwell Drive * Concord, California 94520 * Ph: 925/687-4411 or 800/542-3355 * Fax: 925/687-3333 * www.calex.com * Email: sales@calex.com
3
3/2001
6 Watt Single Series DC/DC Converters
Typical Performance: (Tc = 25C; Full Rated Load).
28S5.1000 EFFICIENCY Vs. LINE INPUT
75 80
28S15.400 EFFICIENCY Vs. LINE INPUT
0.30
28 VOLT INPUT CURRENT Vs. LINE INPUT VOLTAGE
EFFICIENCY (%)
EFFICIENCY (%)
70
75
INPUT CURRENT (AMPS)
100% FULL LOAD
100% FULL LOAD
65
0.20
100% FULL LOAD
70
50% FULL LOAD
0.10
50% FULL LOAD
60
50% FULL LOAD
65
55 26 27 28 29 30 31
60 26 27 28 29 30 31
0.00 10 15 20 25 30 35
LINE INPUT (VOLTS)
LINE INPUT (VOLTS)
LINE INPUT (VOLTS)
OPERATING RANGE
48S5.1000 EFFICIENCY Vs. LINE INPUT
70 80
48S15.400 EFFICIENCY Vs. LINE INPUT
0.20
48 VOLT INPUT CURRENT Vs. LINE INPUT VOLTAGE
100% FULL LOAD
65 75
INPUT CURRENT (AMPS)
EFFICIENCY (%)
EFFICIENCY (%)
0.15
100% FULL LOAD
60
100% FULL LOAD
70
0.10
50% FULL LOAD
65
50% FULL LOAD
55
50% FULL LOAD
60
0.05
50 44 46 48 50 52 54
55 44 46 48 50 52 54
0.00 25 30 35 40 45 50 55
LINE INPUT (VOLTS)
LINE INPUT (VOLTS)
LINE INPUT (VOLTS)
24S5.1000 EFFICIENCY Vs. LOAD
75 80
24S15.400 EFFICIENCY Vs. LOAD
1
OUTPUT IMPEDANCE Vs. FREQUENCY
LINE = 22.32VDC
65
LINE = 22.32VDC
EFFICIENCY (%)
EFFICIENCY (%)
70
IMPEDANCE (OHMS)
LINE = 24VDC LINE = 26.4VDC
LINE = 24VDC LINE = 26.4VDC
60
.1
15V OUTPUT
55
5V OUTPUT
.01
45
50
35 0 20 40 60 80 100
40 0 20 40 60 80 100
.001 10 100 1K 10K 100K 1M
LOAD (%)
LOAD (%)
FREQUENCY (Hz)
A
2401 Stanwell Drive * Concord, California 94520 * Ph: 925/687-4411 or 800/542-3355 * Fax: 925/687-3333 * www.calex.com * Email: sales@calex.com
4
3/2001


▲Up To Search▲   

 
Price & Availability of 12S12500

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X